Home  > Electrical Feedthroughs > EFT ACCESSORIES > CONNECTORS AND CABLES / CIRCULAR CONNECTORS - 3 TO 7 PINS > To 700V- to I OA- air and vacuum service to 350C

Product Listing

To 700V- to I OA- air and vacuum service to 350C

Although these connectors do not carry the MS prefix, they are of the MS type. Other than the alumina ceramic dielectric, these connectors meet standard specifications for MIL-C-50 IS connectors. They are solid shell straight plug threaded connectors with polarizing keyways. The female socket contacts are Alumel®, a high nickel alloy suitable for service in air or vacuum and bakeable to 350°C. The metal shell components are nickel plated aluminium with low vapour pressure characteristics, unlike standard MS circular connectors which are cadmium plated and not suitable for UHV.

Features

Air and vacuum service to 350°C - CON23-IV1O



Click image to enlarge

Click image to enlarge


Click image to enlarge


WIRING INSTRUCTIONS


Click image to enlarge

Step 1 : Slide the cable clamp, back shell and
nut (in that order) over cable, then strip each
conductor 6mm as detailed.



Click image to enlarge

Step 2 : Remove retainer ring from front shell and
disassemble by sliding insulators and contacts. Note
that insulator consists of front and back pieces.
Insert wires through the appropriate sides in back
insulator before crimping contacts.


Click image to enlarge

Step 3 : Slide contacts on to wire and crimp in place.






Click image to enlarge

Step 4 : Insert crimped contacts into appropriate
holes in front insulator. Note alignment slots on
insulators.



Click image to enlarge

Step 5 : Slide the front and back insulators
together and insert them into the front shell.
Secure them in place with the retainer ring.




Click image to enlarge

Step 6 : Slide the nut over the front shell, then
thread the back shell on to the front shell and
tighten. Thread the clamp on to the back shell and
tighten. Moderately tighten clamp screws to
provide adequate strain relief to wire and contacts.





For any question on this Section Ask Our Experts



Drawings download if available are indicated by in the Part Number column. Click on this icon to view all downloads.
Literature downloads (including manuals), if available, is indicated by in the Part Number column. Click on this icon to view all available product literature and to download a PDF copy.

Catalog